品牌/型号:CONDY/康狄制冷/YL
加工定制:否
类型:冷却机
品牌:CONDY/康狄制冷
型号:YL
标准制冷量:见产品(kw)
输入功率:见产品(kw)kw
外形尺寸:见产品mm
重量:见产品(kg)kg
应用领域:见产品
结构类型:见产品
'
YL精密油冷却机 YL PRECISION OIL CHILLER 适用种类 CNC车床、铣床、磨床、拉床 CNC综合加工中心 油压机、雕刻机 各种机械的液压站及润滑系统 放电加工机 Application CNC lathe. Milling machine, Grinder. Broach maching CNC machining center Hydraulic press, Carving machine All kinds of mechanical hydros tatic station and Lubrication systcm Electric discharge machine 特性与功能 防止工作机械因油温的变化而影响精度。 防止油质因高温劣化。保持油液粘度不变,使工作机械稳定工作。 油温控制以机体温度(室温)为依据,用户可根据机体温度设定油温,防止机械结构产生热变形。 独立式油冷却机具有完整的吸送油系统与独立的电器控制系统,只要连通油管,就可以与机床连机工作。 机组附有自动报警功能, 可通过特定的方式及时提醒用户对装置进行检修,以免机件损坏。 Features and Functions Avoid changes of machining accuracy due to the changes of oil temperature. Prevent oil quality from deterioraed due to high temperature,and keep its viscosity constantly, thus maintaing stable working performance of machinery. Set up the oil temperture based on the ambient temperature to avoid thermal deformation. Independent oil pumping and electric control systems so that any machine can be worked together with this equipment only by connect-ing them through pipes. Auto alarming function is provided to remind users of inspection and maintainance to avoid any damage of machine. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
规格及技术参数 Technical Specifiication
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
备注 1、制冷能力是在环境温度35℃,进油温度35℃,出油温度30℃,油品为ISO VG32条件下测得。 2、用户在选择油冷机时,必须选择油液需控制的温度范围(1)18℃-25℃ (2)25℃-35℃ (3)35℃-45℃ (4)45℃以上。本公司推荐液压油合理的温度控制范围为35℃-45℃. 3、油冷机吸油口必须用硬管连接,且加装过滤器。 4、吸油管长度不应超过1.5米,如超出必须加粗吸油口。 5、油冷机吸油口应靠近设备回油口,出油口应靠近设备供油口。 6、如吸油口太长,需将油泵与机组分离。 7、以上机组使用环境为5~42℃,42℃以上属高温机组,外形尺寸及相关参数会有所变更,请选型时注意。 8、参数表内为本公司标准机型,本公司接受客户特殊订货。 Remark 1.Above cooling capacity base on the ambient temperature 35℃,oil inlet temperature 35℃,oil outlet temperature 30℃,oil quality is tested under condition ISO VG32. 2.The oil-cooling device is used to the hydraulic oil within 35℃~45℃,(recommended) 3.Oil inlet of chiller should be connectted by hard pipes and filter is mounted. 4.Length of pipe should not exceed 1.5M,if exceed,lager-size interface of oil inlet should be added. 5.Chiller should be close to oil supply inlet of equipment and oil outlet of chiller should be close to oil supply inlet of equipment. 6.Oil pump should be seperated from unit assembly if the oil inlet too long. 7.The chillers introduced above can be used within 5~42℃,if the chillers work above 42℃,the dimension and relative paramater will be changed,please pay more attention to the specification when making a choice. 8.Chiller type on the above table is standard,apeical order on requst. |
'